1 / 5
| Category | Project | Test Conditions | Technical Requirements |
|---|---|---|---|
| Physical properties | Tensile strength /MPa | / | ≥10.4 |
| Elongation at break /% | / | ≥200 | |
| Tensile strength after aging | 158ºC x 168hr | ≥7.3 | |
| Elongation after aging | 158ºC x 168hr | ≥100 | |
| Thermal shock | 250ºC x 4hr | Don't crack | |
| Low softness | -30ºC x 1hr | Don't crack | |
| Electrical properties | Withstand voltage (300V) | UL224 | 1500V No breakdown |
| Withstand voltage (600V) | UL224 | 2500V No breakdown | |
| Volume resistivity | / | ≥1x1014 ω.cm | |
| Chemical properties | Copper stability | 158ºC x 168hr | ≥100 |
| Flame resistance | VW-1 | Pass |